For the uk mains 230v ac 3 28a gives you 754 watts and therefore 60 efficiency.
Server room cooling load.
Window size and position.
Add all the btus together.
Because server room equipment releases so much more heat than any other office location portable air conditioners are the ideal solution for cooling the server room by being location specific with your critical.
Realistically the maximum power under normal operating conditions will be around 650 watts.
The very maximum power this server will consume under 100 load will be 754 watts.
So what size of unit do i need.
P riceless corporate data and tens of thousands of dollars of server room equipment can quickly be at risk for loss if server room temperatures arenĂ¢ t maintained correctly.
When calculating the amount of cooling air conditioning required in a room.
The services may include but are not limited to wide area communications fast and reliable internet access web or application hosting server rent out back up storage facilities content distribution and load sharing with new variations appearing almost daily.
To calculate the area in square metres.
Total heat load room area btu windows btu total occupant btu equipment btu lighting btu.
Re designing the layout of your server room to accommodate bulky built in cooling units is expensive and disrupts the usability of your servers.
The vertiv vrc rack cooling system is designed specifically for fast easy installation in small server rooms network closets and edge computing spaces.
This is the amount of cooling required so you need one or more air conditioning units to handle that amount of heat.
The amount of cooling required depends on the area of the room.
If as is quite common your server room has no windows you can ignore this part of the calculation.
It equipment btu total wattage x 1 5.
Vertiv vrc rack cooling system 3500 watts.
Other larger electrical systems within the room will also add to the btu load.
For safety add a factor into the calculation of 1 5 to allow for future expansion.
Power cooling and facilities infrastructure.
Floor area of room.
Advanced server heat load calculator use the heat load calculator below to estimate the electrical and cooling costs of up to 3 types of servers or devices and determine the estimated heat load that.
For these reasons we have developed these this server btu and cooling calculator to help you plan and prepare proper cooling for your server rooms.
An example being an uninterruptible.
Room area btu length m x width m x 337.